What is the purpose of the roof exit and what should it be characterized by?

Do czego służy wyjście na dach i co powinno je cechować

Such an element is a way out, without which it would be difficult to safely carry out maintenance, repair or cleaning of all the things on top of our property. The construction law is also absolute in this matter. Installation is absolutely necessary when we have at least two floors. There are certain guidelines that determine what dimensions it should be to meet all standards. In this article, you will learn what a proper and safe exit to the roof should have.

You can buy high-quality roof hatches at the Gulajski Company. The full offer can be found on the website: https://www.gulajski.pl/wylaz_dachowy/ We offer consulting, production, design and assembly. Telephone contact: Tel/fax.: +48 (32) 236 30 05

What is a good roof exit

An exit to the roof is a structural element of the roof that allows safe access to its surface. Its main task is to enable easy access to the roof in order to carry out various types of maintenance, repair work or install devices such as antennas, air conditioners or photovoltaic panels. This element should be characterized primarily by high quality workmanship and resistance to weather conditions. It should be easy to install and disassemble and provide safe access to the roof. It is also important that it is easy to open and close, and its design allows for free air flow in the room under the roof.

Thermal and acoustic insulation is also an important aspect. If a polycarbonate outlet with low thermal insulation is used, heat may be lost from the room under the roof, which leads to an increase in heating costs. On the other hand, the lack of acoustic insulation can cause noise from the outside, which negatively affects the comfort of using the room.

This particular element of the roof system must comply with standards and regulations for safety at work at heights and meet fire safety standards.

It must be adapted to the roof and also have special dimensions

A safe exit to the roof is essential in the designs of many buildings. It is worth remembering that the regulations regarding its location are different. For example, people building high-rise properties must provide access to the roof in each staircase. Its location determines its type. The choice of manhole must take into account the angle of inclination and the material. Parameters such as tightness and resistance to weather conditions are also important. The minimum dimensions are 80 x 80 cm. In our assortment you will find a wide range of such products that will perfectly fit all needs. The Gulajski company takes into account the wishes of customers, adapting the version to any prescribed size. We provide professional advice and select the best solutions.

What is the purpose of the roof exit and what should it be characterized by?

The selection of the right exit to the roof should depend on the type of roof and its angle of inclination. The exit should be of the right size and shape so that it fully corresponds to the shape of the roof and fulfills its functions in an optimal way. The dimensions should be selected in such a way as to allow free access to the roof and to ensure ease and safety of movement on its surface. It should also be properly sealed to prevent moisture and other weather agents from entering the room under the roof. You should also pay attention to the type of opening. The most common are those that open to the sides or upwards, but depending on your needs, you can also choose other solutions, e.g. with doors or with a lifting system.

You can buy high-quality roof hatches at the Gulajski Company. The full offer can be found on the website: https://www.gulajski.pl/wylaz_dachowy/ We offer consulting, production, design and assembly. Telephone contact: Tel/fax.: +48 (32) 236 30 05

Gulajski has 20 years of experience in the industry. Trust our specialists!

You will find polycarbonate roof mounts with us. They are characterized by the best properties, including reliable tightness. We are a specialist in the industry. For years, we have been taking care of adequate lighting in many places in Poland, but also in Europe. It is worth knowing that we provide a 12-month warranty for each of our products. Our solutions also have an extremely important smoke extraction function. We guarantee competitive prices and comprehensive service, which includes design, workmanship and installation. If you have any questions, we will be happy to pick up the phone. We invite you to familiarize yourself with our wide offer!

Technical conditions

In the process of designing roof exits, it is important to take into account several key aspects. The most important thing is that the size is adjusted so that it ensures comfortable and safe use, both when opening and closing, as well as when going up and off the roof. The dimensions of the access window should be consistent with the size of the roof opening. If the roof access window is already installed, it is necessary to precisely measure its dimensions in order to choose a product with the right dimensions.

Technical conditions for the installation of roof systems

The size of the roof access window must comply with the applicable standards and regulations. In accordance with the Regulation of the Minister of Infrastructure of 12 April 2002 on the technical conditions of buildings and their location, the minimum width of the access window should be 800 mm, and the minimum height should be 1000 mm. In accordance with the Regulation of the Minister of Internal Affairs and Administration of 7 June 2010 on fire protection of buildings and areas, the minimum area of the roof access window serving as an escape route should be 1.20 m², with the minimum dimensions of 80 cm x 150 cm. In addition, the emergency exit must be equipped with a ladder or stairs to allow access to the roof and handrails to prevent falls.

Is it mandatory to install on a flat roof?

This element is required in buildings with two or more above-ground storeys. In accordance with the Regulation of the Minister of Infrastructure of 12 April 2002 on the technical conditions of buildings and their location, it is necessary to provide access to the roof from at least one staircase, which allows access to technical equipment installed on the roof. In high-rise (W) and high-rise (WW) buildings, such exits should be accessible from every staircase.

A door 0.8 m wide and at least 1.9 m high or access hatches with dimensions of 0.8 × 0.8 m in the clear may be used as an exit from the staircase to the roof, provided that access to them should meet the conditions set out in § 101.

In the case of roofs with a slope of more than 25% and covered with brittle (breakable) materials, permanent access to chimneys, technical devices and radio and television antennas should be ensured. On roofs with a slope of more than 100%, fixed brackets for safety ropes or safety barriers should be installed over the lower edge of the roof.

Energy efficiency

Energy efficiency is a key aspect when choosing the right roof access windows for flat-roof buildings. The Gulajski company, as a renowned manufacturer of roof hatches, is aware of the role that these elements play in the energy efficiency of the building. Our products have been carefully designed, taking into account a number of important factors that affect the comfort of use and energy savings.

One of the key parameters we pay attention to is the heat transfer coefficient, or U-value. Our products are characterized by low U-values, which translates into excellent thermal insulation and minimal heat loss. This effectively increases the energy efficiency of the building, reducing both heating and cooling costs.

In addition, our polycarbonate products are characterized by high acoustic insulation. By introducing them into the building, we ensure that external noise is reduced, which promotes a calm and pleasant indoor environment. Whether your building is located on a busy street or close to other sources of noise, our solutions effectively minimise the impact on your daily life.

Tightness is another important element that we pay attention to. Thanks to the careful design and use of high-quality seals and tight connections, our roofing systems provide excellent airtightness. This avoids unwanted air leaks and maintains effective thermal insulation, contributing to long-term energy savings.